Ningbo XiaoYang Science and Technology Co., Ltd.
language
Put Pure sine wave 1500W with UPS up  for sale

Put Pure sine wave 1500W with UPS up for sale

Product Features
1. Pure sine wave output waveform, strong load ability, wide application;
2. High transform efficiency, fast start, small no load current;
3. Soft start function; reduce load’s starting risk;
4. Perfect protection, with low voltage, over voltage, over load, over temperature, short circuit, input reverse connection protections and etc.;
5. Intelligent temperature control fan, when loads over 30%, it will start. Saving energy, safe and high efficiency;
6. Imported electronic Components; built-in fuse, safe and reliable;
7. with built-in AC three-stage charging mode, automatically adjust charging current;
8. with built-in AC Bypass Relay (<10ms), realizing uninterrupted AC output

Put Pure sine wave 1500W with UPS up for sale parameters

Model BTP-1500-121 BTP-1500-241 BTP-1500-481 BTP-1500-122 BTP-1500-242 BTP-1500-482
Continuous Output Power 1500W 1500W 1500W 1500W 1500W 1500W
Peak Power 3000W (<5ms)
DC Input Voltage 12V 24V 48V 12V 24V 48V
AC Output Voltage 110VAC±10% 220VAC±5%
No-load Current <1.6A(DC13V) <1.05A(DC26V) <0.75A(DC52V) <1.6A(DC13V) <1.05A(DC26V) <0.75A(DC52V)
AC Output Frequency 50HZ±1%/60HZ±1%
AC Output Waveform Pure Sine Wave
Waveform Distortion THD<3%(Linear load)
Efficiency >86%(DC13V) >88%(DC26V) >90%(DC52V) >86%(DC13V) >88%(DC26V) >90%(DC52V)
AC Input Voltage Range 88V~135V(±8V) 88V~135V(±8V) 88V~135V(±8V) 196V~270V(±16V) 196V~270V(±16V) 196V~270V(±16V)
DC Input Voltage Range 11V~15V 22V~30V 44V~60V 11V~15V 22V~30V 44V~60V
Low Voltage Protection 10±0.2V 20±0.4V 40±0.8V 10±0.2V 20±0.4V 40±0.8V
Over Voltage Protection 15.5±0.5V 31.0±1.0V 62±2.0V 15.5±0.5V 31.0±1.0V 62±2.0V
Low Voltage Recovery 13.6±0.3V 27.2±0.6V 54.4±1.2V 13.6±0.3V 27.2±0.6V 54.4±1.2V
Over Voltage Recovery 15.2±0.5V 30.4±1.0V 60.8±2.0V 15.2±0.5V 30.4±1.0V 60.8±2.0V
Over Load Protection 120%~125%
Charging Current 15A 10A 5A 15A 10A 5A
Charging Maximum Voltage 14.7 29.4 58.8 14.7 29.4 58.8
Charging Mode Connected with mains supply, constant current,constant voltage, floating charge
Working Mode When there is electricity, inverter outputs lectricity, and red light is on; when there is no electricity, it will automatically switch to use battery power and red light turns off. As long as there is electricity and battery is not full, charger will charge it.
Protective Function Low voltage: LED red light, Buzzer alarm, automatic recovery
Over voltage: LED red light, automatic recovery
Over load: LED red light, automatic shut down, need restart
Over temperature: LED red light, Buzzer alarm, automatic recovery
Short circuit (within 2s): automatic recovery
Input reverse connection: fuse burn-out
Working Temp. -10°C-40°C
Storage Temp. -30°C-70°C
Humidity 20%~90%RH Non-condensing
Working Altitude ≦3000m
Machine Size 514*199*73mm
Net Weight 6.2±0.5kg
Packing Size 530*300*240mm
Gross Weight 7.6±0.5kg 7.4±0.5kg 7.2±0.5kg 7.6±0.5kg 7.4±0.5kg 7.2±0.5kg