Product Features
1. Pure sine wave output waveform, strong load ability, wide application;
2. High transform efficiency, fast start, small no load current;
3. Soft start function; reduce load’s starting risk;
4. Perfect protection, with low voltage, over voltage, over load, over temperature, short circuit, input reverse connection protections and etc.;
5. Intelligent temperature control fan, when loads over 30%, it will start. Saving energy, safe and high efficiency;
6. Imported electronic Components; built-in fuse, safe and reliable;
7. with built-in AC three-stage charging mode, automatically adjust charging current;
8. with built-in AC Bypass Relay (<10ms), realizing uninterrupted AC output
Model | BTP-2500-121 | BTP-2500-241 | BTP-2500-481 | BTP-2500-122 | BTP-2500-242 | BTP-2500-482 |
Continuous Output Power | 2500W | 2500W | 2500W | 2500W | 2500W | 2500W |
Peak Power | 5000W (<5ms) | |||||
DC Input Voltage | 12V | 24V | 48V | 12V | 24V | 48V |
AC Output Voltage | 110VAC±10% | 220VAC±5% | ||||
No-load Current | <1.8A(DC13V) | <1.11A(DC26V) | <0.9A(DC52V) | <1.8A(DC13V) | <1.11A(DC26V) | <0.9A(DC52V) |
AC Output Frequency | 50HZ±1%/60HZ±1% | |||||
AC Output Waveform | Pure Sine Wave | |||||
Waveform Distortion | THD<3%(Linear load) | |||||
Efficiency | >86%(DC13V) | >88%(DC26V) | >90%(DC52V) | >86%(DC13V) | >88%(DC26V) | >90%(DC52V) |
AC Input Voltage Range | 88V~135V(±8V) | 88V~135V(±8V) | 88V~135V(±8V) | 196V~270V(±16V) | 196V~270V(±16V) | 196V~270V(±16V) |
DC Input Voltage Range | 11V~15V | 22V~30V | 44V~60V | 11V~15V | 22V~30V | 44V~60V |
Low Voltage Protection | 10±0.2V | 20±0.4V | 40±0.8V | 10±0.2V | 20±0.4V | 40±0.8V |
Over Voltage Protection | 15.5±0.5V | 31.0±1.0V | 62±2.0V | 15.5±0.5V | 31.0±1.0V | 62±2.0V |
Low Voltage Recovery | 13.6±0.3V | 27.2±0.6V | 54.4±1.2V | 13.6±0.3V | 27.2±0.6V | 54.4±1.2V |
Over Voltage Recovery | 15.2±0.5V | 30.4±1.0V | 60.8±2.0V | 15.2±0.5V | 30.4±1.0V | 60.8±2.0V |
Over Load Protection | 120%~125% | |||||
Charging Current | 15A | 10A | 5A | 15A | 10A | 5A |
Charging Maximum Voltage | 14.7 | 29.4 | 58.8 | 14.7 | 29.4 | 58.8 |
Charging Mode | Connected with mains supply, constant current,constant voltage, floating charge | |||||
Working Mode | When there is electricity, inverter outputs lectricity, and red light is on; when there is no electricity, it will automatically switch to use battery power and red light turns off. As long as there is electricity and battery is not full, charger will charge it. | |||||
Protective Function | Low voltage: LED red light, Buzzer alarm, automatic recovery | |||||
Over voltage: LED red light, automatic recovery | ||||||
Over load: LED red light, automatic shut down, need restart | ||||||
Over temperature: LED red light, Buzzer alarm, automatic recovery | ||||||
Short circuit (within 2s): automatic recovery | ||||||
Input reverse connection: fuse burn-out | ||||||
Working Temp. | -10°C-40°C | |||||
Storage Temp. | -30°C-70°C | |||||
Humidity | 20%~90%RH Non-condensing | |||||
Working Altitude | ≦3000m | |||||
Machine Size | 444*199*146mm | |||||
Net Weight | 8.6±0.05kg | 8.45±0.05kg | 8.3±0.05kg | 8.6±0.05kg | 8.45±0.05kg | 8.3±0.05kg |
Packing Size | 560*290*240mm | |||||
Gross Weight | 9.6±0.05kg | 9.45±0.05kg | 9.3±0.05kg | 9.6±0.05kg | 9.45±0.05kg | 9.3±0.05kg |