Product Features
1. Pure sine wave output waveform, strong load ability, wide application;
2. High transform efficiency, fast start, small no load current;
3. Soft start function; reduce load’s starting risk;
4. Perfect protection, with low voltage, over voltage, over load, over temperature, short circuit, input reverse connection protections and etc.;
5. Intelligent temperature control fan, when loads over 30%, it will start. Saving energy, safe and high efficiency;
6. Imported electronic Components; built-in fuse, safe and reliable;
7. Three-stage intelligent charging, effectively protection of the battery.
Model | BTP-2000-121 | BTP-2000-241 | BTP-2000-481 | BTP-2000-122 | BTP-2000-242 | BTP-2000-482 |
Continuous Output Power | 2000W | 2000W | 2000W | 2000W | 2000W | 2000W |
Peak Power | 4000W (<5ms) | |||||
DC Input Voltage | 12V | 24V | 48V | 12V | 24V | 48V |
AC Output Voltage | 110VAC±10% | 220VAC±5% | ||||
No-load Current | <1.7A(DC13V) | <1.05A(DC26V) | <0.85A(DC52V) | <1.7A(DC13V) | <1.05A(DC26V) | <0.85A(DC52V) |
AC Output Frequency | 50HZ±1%/60HZ±1% | |||||
AC Output Waveform | Pure Sine Wave | |||||
Waveform Distortion | THD<3%(Linear load) | |||||
Efficiency | >86%(DC13V) | >88%(DC26V) | >90%(DC52V) | >86%(DC13V) | >88%(DC26V) | >90%(DC52V) |
DC Input Voltage Range | 11V~15V | 22V~30V | 44V~60V | 11V~15V | 22V~30V | 44V~60V |
Low Voltage Alarm | 10.5±0.3V | 21±0.6V | 41.8±1.2V | 10.5±0.3V | 21±0.6V | 41.8±1.2V |
Low Voltage Shutdown | 9.5±0.2V | 19±0.3V | 38±0.4V | 9.5±0.2V | 19±0.3V | 38±0.4V |
Over Voltage Protection | 16±0.5V | 31±1V | 65±2V | 16±0.5V | 31±1V | 65±2V |
Low Voltage Recovery | 11.8±0.3V | 23.6±0.4V | 47.2±0.8V | 11.8±0.3V | 23.6±0.4V | 47.2±0.8V |
Over Voltage Recovery | 15.7±0.3V | 31.8±0.4V | 63±1V | 15.7±0.3V | 31.8±0.4V | 63±1V |
Over Load Protection | 120%~125% | |||||
Charging Current | 15A | 10A | 5A | 15A | 10A | 5A |
Charging Maximum Voltage | 14.7 | 29.4 | 58.8 | 14.7 | 29.4 | 58.8 |
Charging Mode | Connected with mains supply, constant current,constant voltage, floating charge | |||||
Protective Function | Low voltage: LED red light, Buzzer alarm, automatic recovery | |||||
Over voltage: LED red light, automatic recovery | ||||||
Over load: LED red light, automatic shut down, need restart | ||||||
Over temperature: LED red light, Buzzer alarm, automatic recovery | ||||||
Short circuit (within 2s): automatic recovery | ||||||
Input reverse connection: fuse burn-out | ||||||
Working Temp. | -10°C-40°C | |||||
Storage Temp. | -30°C-70°C | |||||
Humidity | 20%~90%RH Non-condensing | |||||
Working Altitude | ≦3000m | |||||
Machine Size | 514*199*73mm | |||||
Net Weight | 6.6±0.05kg | 6.45±0.05kg | 6.3±0.05kg | 6.6±0.05kg | 6.45±0.05kg | 6.3±0.05kg |
Packing Size | 530*300*240mm | |||||
Gross Weight | 7.6±0.05kg | 7.45±0.05kg | 7.3±0.05kg | 7.6±0.05kg | 7.45±0.05kg | 7.3±0.05kg |